STRINGS(1P) | POSIX Programmer's Manual | STRINGS(1P) |
PROLOG¶
This manual page is part of the POSIX Programmer's Manual. The Linux implementation of this interface may differ (consult the corresponding Linux manual page for details of Linux behavior), or the interface may not be implemented on Linux.
NAME¶
strings - find printable strings in files
SYNOPSIS¶
strings [-a][-t format][-n number][file...]
DESCRIPTION¶
The strings utility shall look for printable strings in regular files and shall write those strings to standard output. A printable string is any sequence of four (by default) or more printable characters terminated by a <newline> or NUL character. Additional implementation-defined strings may be written; see localedef.
OPTIONS¶
The strings utility shall conform to the Base Definitions volume of IEEE Std 1003.1-2001, Section 12.2, Utility Syntax Guidelines.
The following options shall be supported:
- -a
- Scan files in their entirety. If -a is not specified, it is implementation-defined what portion of each file is scanned for strings.
- -n number
- Specify the minimum string length, where the number argument is a positive decimal integer. The default shall be 4.
- -t format
- Write each string preceded by its byte offset from the start of the file. The format shall be dependent on the single character used as the format option-argument:
- d
OPERANDS¶
The following operand shall be supported:
- file
- A pathname of a regular file to be used as input. If no file operand is specified, the strings utility shall read from the standard input.
STDIN¶
See the INPUT FILES section.
INPUT FILES¶
The input files named by the utility arguments or the standard input shall be regular files of any format.
ENVIRONMENT VARIABLES¶
The following environment variables shall affect the execution of strings:
- LANG
- Provide a default value for the internationalization variables that are unset or null. (See the Base Definitions volume of IEEE Std 1003.1-2001, Section 8.2, Internationalization Variables for the precedence of internationalization variables used to determine the values of locale categories.)
- LC_ALL
- If set to a non-empty string value, override the values of all the other internationalization variables.
- LC_CTYPE
- Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi-byte characters in arguments and input files) and to identify printable strings.
- LC_MESSAGES
- Determine the locale that should be used to affect the format and contents of diagnostic messages written to standard error.
- NLSPATH
- Determine the location of message catalogs for the processing of LC_MESSAGES .
ASYNCHRONOUS EVENTS¶
Default.
STDOUT¶
Strings found shall be written to the standard output, one per line.
When the -t option is not specified, the format of the output shall be:
"%s", <string>
With the -t o option, the format of the output shall be:
"%o %s", <byte offset>, <string>
With the -t x option, the format of the output shall be:
"%x %s", <byte offset>, <string>
With the -t d option, the format of the output shall be:
"%d %s", <byte offset>, <string>
STDERR¶
The standard error shall be used only for diagnostic messages.
OUTPUT FILES¶
None.
EXTENDED DESCRIPTION¶
None.
EXIT STATUS¶
The following exit values shall be returned:
- 0
- Successful completion.
- >0
- An error occurred.
CONSEQUENCES OF ERRORS¶
Default.
The following sections are informative.
APPLICATION USAGE¶
By default the data area (as opposed to the text, "bss", or header areas) of a binary executable file is scanned. Implementations document which areas are scanned.
Some historical implementations do not require NUL or <newline> terminators for strings to permit those languages that do not use NUL as a string terminator to have their strings written.
EXAMPLES¶
None.
RATIONALE¶
Apart from rationalizing the option syntax and slight difficulties with object and executable binary files, strings is specified to match historical practice closely. The -a and -n options were introduced to replace the non-conforming - and - number options.
The -o option historically means different things on different implementations. Some use it to mean " offset in decimal", while others use it as " offset in octal". Instead of trying to decide which way would be least objectionable, the -t option was added. It was originally named -O to mean "offset", but was changed to -t to be consistent with od.
The ISO C standard function isprint() is restricted to a domain of unsigned char. This volume of IEEE Std 1003.1-2001 requires implementations to write strings as defined by the current locale.
FUTURE DIRECTIONS¶
None.
SEE ALSO¶
localedef, nm
COPYRIGHT¶
Portions of this text are reprinted and reproduced in electronic form from IEEE Std 1003.1, 2003 Edition, Standard for Information Technology -- Portable Operating System Interface (POSIX), The Open Group Base Specifications Issue 6, Copyright (C) 2001-2003 by the Institute of Electrical and Electronics Engineers, Inc and The Open Group. In the event of any discrepancy between this version and the original IEEE and The Open Group Standard, the original IEEE and The Open Group Standard is the referee document. The original Standard can be obtained online at http://www.opengroup.org/unix/online.html .
2003 | IEEE/The Open Group |